Filter Results By:

Products

Applications

Manufacturers

Calibration References

A qualified quantified source of known value.

See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services


Showing results: 61 - 75 of 118 items found.

  • Digital Pressure Gauges

    WIKA Alexander Wiegand SE & Co. KG

    Precision digital pressure gauges are suitable for stationary and also mobile measurement and display of pressures. In addition, a digital pressure gauge can be used as a pressure reference and enables the easy testing, adjustment and calibration of other pressure measuring equipment directly on-site. Through efficient measuring cells with electronic linearisation of the characteristic curve, a high accuracy is achieved.

  • Digital Pressure Gauge

    Mensor Corp.

    Precision digital pressure gauges are suitable for stationary and also mobile measurement and display of pressures. In addition, a digital pressure gauge can be used as a pressure reference and enables the easy testing, adjustment and calibration of other pressure measuring equipment directly on site. Through efficient measuring cells with electronic linearisation of the characteristic curve, a high accuracy is achieved.

  • Hydrophone

    RESON TC 4035 - Teledyne Marine RESON B.V.

    ​The TC4035 is a miniature probe hydrophone specifi cally designed as a standard reference hydrophone for sound measurements in the frequency range 100 to 500kHz. The hydrophone incorporates a 10dB low-noise preamplifier, which includes an insert calibration circuit for convenient electrical testing of the hydrophone condition. The pre-amp has a drive capability for cable length up to 25 meters.

  • Meter Test System

    MTS-122 - Kongter Test & Measurement Co., Limited

    This rugged Meter Test System is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 36A). This system is particularly designed with modular structure for calibration and test of analog meter, digital meter, RTU, electrical transducer, energy meter and so on. It is operated under high functionality with user friendly interface.

  • Handheld Water Quality Meters

    LAQUA EC210 - HORIBA, Ltd.

    - Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data - Auto stable, auto hold, and real-time measurement modes- Auto shut-off (programmable: up to 30 minutes)- Monochrome LCD with white LED backlight: 50 x 50 mm- Powered by 2 x AA batteries - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty

  • Decade Capacitor

    GenRad 1423-A - IET Labs

    The GenRad 1423 decade capacitor is a versatile tool for calibration laboratories and production-line testing. With it a bridge can be standardized to an accuracy exceeded only by that of the highest quality, individually certified laboratory standards such as the GR 1404 Reference Standard Capacitors.Used with a limit bridge, such as the GR 1689 Digibridge, the 1423 facilities fast and accurate production-line measurements of arbitrary capacitancevalues with minimum setup time.

  • Solar Cell I-V Characterization System

    VS6821 - Industrial Vision Technology Pte Ltd.

    This system provides cell manufactures and laboratories a new way in testing and measuring photovoltaic cells. Integrated with Steady-State Solar Simulator, it provides complete coverage of testing parameters and measurement requirements by most international standards. Its test methods, procedure & equipment are IEC 60904 compliant. Calibration of reference cell is performed at Fraunhofer ISE in Germany, and is traceable to PTB.

  • Meter Testing System

    ASTel - Radian Research, Inc.

    Three-phase Meter Test Equipment of ASTeL 3.2x.x series system is a fully automatic system enabling simultaneous, multi-position calibration and legalization of electric energy meters. The automatics include power sources, reference standards, stand controllers, photoelectric scanning heads, separating transformers, and other elements of the system. All these elements are controlled through a Windows based executive program.

  • Portable Calibration Baths

    6109A / 7109A - Fluke Calibration

    The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.

  • Handheld Water Quality Meters

    LAQUA PC210 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty

  • Multi-Scanners

    AMETEK Sensors, Test & Calibration

    We offer a signal multi-scanner which provides a time-saving, automatic solution to calibrate multiple temperature or pressure sensors simultaneously. The scanner may be combined with our dry-block or liquid calibrators, DTI reference thermometers, pressure calibrators, and ASC multifunction process calibrators. Use any place where temperature and/or pressure measurement is critical and there is a need to create traceable documents for sensor calibration.

  • Chilled Mirror Hygrometers

    Alpha Moisture Systems

    Model CMH-RPC Chilled Mirror Hygrometer utilises a 3-stage Peltier cooler combined with an integral refrigeration unit to measure the water dewpoint (Td) in gases from below -90ºC to +20ºC (-130ºF to +68ºF)This primary measurement technique makes Model CMH-RPC the ideal instrument for laboratory, scientific and research applications, being especially suited as a reference instrument for checking and calibration of process and portable hygrometers.

  • Signal Conditioners

    General Purpose - Encore Electronics, Inc.

    Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.

  • Oscilloscope App

    ONYX Apps

    Oscilloscope for iOS is great for analyzing audio range signals, or learning oscilloscope measurement basics. The interface includes many standard oscilloscope controls, such as: triggering, time and voltage per division, signal measurement cursors, and more. The app incorporates a signal (function) generator capable of generating sine, square, triangle, and sawtooth waveforms of up to 22 KHz. Calibration to an external reference signal is supported, guaranteeing the accuracy of measurements.

  • Platforms

    AMETEK VTI Instruments

    The use of switching systems to route instrumentation and stimulus signals to appropriate test points on a unit under test has a very crucial role to play in most electronics test systems. The sharing of test resources, connection of calibration references, load management, and many other functions are all managed by the switching system, the switching system acts as the interface between the unit under test (UUT) and the test equipment.

Get Help